關於高效過濾器(qì)的更換(huàn)周期(qī)方麵的(de)問題,很多潔淨室用戶都很關心,畢竟高效過濾器決定著潔淨室的潔淨度能否(fǒu)達到標準,就在前方嫩草影院也整理過相關方麵的問題(tí):高效(xiào)過濾器的更換標準

In the pharmaceutical industry, HEPA filters are used as terminal filters for the processing or filtration of air in production spaces. They are mandatory in sterile production, although they are sometimes also used in the manufacture of solid or semisolid dosage forms. Amongst the HEPA or high-efficiency particulate air filters are Filter Classes H13 to H14 (DIN 1822), the latter with a retention rate of 99.995%. But how often do they need to be changed?

在製藥行業,高效過濾(lǜ)器(HEPA)用於生產空間空氣的處理和過(guò)濾(lǜ)的終端過濾(lǜ)器。無菌生產要求強製使(shǐ)用高效過濾器,而固體和(hé)半固體劑型的生產有時也會使用。H13至H14(DIN1822)是高效過濾(lǜ)器的兩種,後者截(jié)留率(lǜ)為99.995%。但(dàn)多久必須(xū)更換一次呢(ne)?

One can frequently find internal company guidelines according to which the filters should be changed annually, regardless of monitoring results. Is that sensible? An exact number, meaning the maximum duration of use for HEPA filters in months, cannot be found in the relevant GMP guidelines. According to GMP, the filter has to be free of leaks. This is verified by qualification and regularly performed leak tests as per ISO 14644-3, which are mandatory for sterile facilities. According to the technical 參考:(www.ljinghua.com)interpretation of the Annex 1 (PIC/S PI 032-2), leak tests are to be performed every six months in A/B zones and every twelve months in C/D zones. The FDA Aseptic Guide demands a regular inspection. The requirements of Annex 1 can be applied here as well. Leaks may be repaired; those repaired areas may only take up 0.5% of the filter surface per filter.

製藥廠高效過濾(lǜ)器一般多久更換?

嫩草影院經常(cháng)看到在公司內部文件(jiàn)中,要求每年(nián)更換過濾器,而(ér)不管檢測結果(guǒ)如何。這是否合理?在相關的(de)GMP指南中並沒有高效過濾器可以使(shǐ)用期限的具體數值。根據GMP的要求,過(guò)濾器不得有泄漏,這需要通過確認(rèn)和定期執行ISO14644-3中的泄漏測試,無(wú)菌(jun1)車間來說這是必須的。根據附錄1(PIC/S PI032-2)的技術詮釋,A/B級每(měi)6個月進行泄漏測試,C/D級則為12個月。FDA無菌指南要(yào)求進行定期檢查。附錄1的要求在這裏也適用。泄漏是(shì)可以修補的,但修補的麵積不能(néng)超過單個(gè)過濾器麵積(jī)的(de)0.5%。)

However, not only the integrity of the HEPA filter is relevant. The load of the filter (layer) and thus the pressure drop at the filter is also important. If the pressure drop at the filter rises, the energy demand of the ventilation system increases to maintain the necessary air change rates. This pressure drop at the filter can increase to the performance limits of the ventilation system. To protect the HEPA filters, preliminary filters are used - usually fine particulate air filters like F7 und F9 filters (EN779). Those have to be replaced regularly and protect the HEPA filters from clogging.

當然,廣州靈潔淨化高效過濾(lǜ)器並不隻有完整性一件事情。過濾(lǜ)器(qì)(層)的負(fù)載以及(jí)上(shàng)下遊壓差也很重要。如果過濾器上下遊壓差升高,則送排風係統的能量需求會增加,這樣才能維持必須的(de)換氣次數。這樣的過濾器上下(xià)遊壓差可能(néng)會增加通風係(xì)統的性能限製。為了保護高效過濾器,就要使用前端過濾器(qì)---通常(cháng)是像F7和F9過濾器(EN779)這樣的(de)精細過濾器。這些過濾器必須(xū)定期更換以保護高效(xiào)過濾器避免堵塞

From a practical viewpoint, one could say that the maximum duration of use depends directly on the pressure drop. Changing the filters only makes sense if the pressure drop gets too high for the performance of the ventilation system or if the cost of energy demand lies above the cost of a filter change. The filters do have to pass the leak tests (see above), of course. In practice, several companies do not use a filter for more than eight years. As mentioned before, though, this is not a legally binding value, but merely based on experience.

從(cóng)實踐(jiàn)角度來看,嫩草影院可以說最長使用期限(xiàn)直接取決於上下遊壓差。隻有在上下遊壓差達到一定數值影響到通風係統的性能,或者是能量需求超過過濾(lǜ)器更換成本時,過濾器更(gèng)換才(cái)有意義。但是,過濾器必須能通過泄漏測試(如上所述)。事(shì)實上,很多公司並不會使用一個過濾器超(chāo)過8年。正如前述,並沒有法(fǎ)規規定這樣的值,這都隻是根據經驗得來(lái)的。

靈潔高(gāo)效過濾器(qì)更換問題

谘詢(xún)內容:老師您好,小容量注射劑車間空調係統的高(gāo)效過濾器必須定期更換嗎?如不定期更換,隻在空(kōng)調驗證時更換風量(liàng)不合格房(fáng)間高效和撿漏不合格高效可以嗎?

CFDA審(shěn)核查驗中心(xīn)回複:你(nǐ)好,更換高(gāo)效過濾器根據空調驗證參(cān)考:時風(fēng)量和撿漏是必須的,但同時也應製定出具體(tǐ)高(gāo)效過濾器最長使用周期,故還是應該有定期的概念(niàn)。同(tóng)時必須定期進行過濾器完整(zhěng)性測試。

製藥廠高效過濾器一般多久更換?

潔淨區A級高效過濾器檢漏

谘詢內(nèi)容:潔淨區A級高效過濾(lǜ)器檢漏是否(fǒu)可以使用 塵埃(āi)粒子計數器 掃描檢(jiǎn)漏(lòu),如(rú)果可以,那麽判斷無(wú)泄漏的標準是多少。

CFDA審核(hé)查驗中心回複:靈潔高效過濾(lǜ)器檢(jiǎn)漏一(yī)般在非關鍵區域可以使用塵埃粒子計數器,但A級潔(jié)淨區(qū)高效過濾器不推薦使用塵埃粒子計數器掃描檢漏


本文網址:http://www.tchengjia.com/product/645.html

關鍵詞:藥廠高效過濾器,製藥高效過濾器,潔淨室高(gāo)效過濾器

最近瀏覽:

在線(xiàn)留言
您的姓名:
您的電話:
留言內容:
聯係(xì)嫩草影院

聯  係(xì) 人:龔經理

電      話:13710142110

傳      真:020-84550845

郵      編:510000

網(wǎng)      址:www.tchengjia.com

郵      箱:lingjie@gdlingjie.com 

地      址:廣州市南沙(shā)區欖核(hé)鎮廣(guǎng)珠路31號



二維碼

IMG_8766(20251027-083516).jpg

Copyright 2018,廣州靈潔(jié)空氣淨化設備官方網站版權所有   備案號(hào):粵ICP備12000047號-6   技術支持:廣州靈潔

  • 在線客服
  • 聯係電話
    18925142386
  • 在線留言
  • 手機網站
  • 在線谘(zī)詢
    歡迎給(gěi)嫩草影院留言
    請在此(cǐ)輸入留言內容,嫩草影院會盡(jìn)快與您聯係。
    姓(xìng)名
    聯係人
    電話
    座機/手(shǒu)機號碼
    郵箱
    郵箱
    地址
    地(dì)址
    嫩草影院_成人嫩草影院入口一二三_亚洲国产精品嫩草影院永久_嫩草影院在线观看网站